Fire Rated Door Supply
Product sourcing and specification coordination for fire door requirements in commercial and industrial projects.
- Steel and metal door options
- Single and double-leaf configurations
- Project-specific sizes and finishes
Fire rated door solutions for commercial buildings, factories, warehouses and industrial facilities in Bangladesh. Get support with product selection, installation requirements, hardware and project quotations.
Fire rated doors form an important part of passive fire protection. A properly specified and installed fire door assembly helps maintain the intended fire separation between designated areas for its rated period.
AJ Fire Safety & Engineering Solutions provides fire door supply and installation enquiries, product specification coordination and project-based service support. Final selection depends on the approved design, opening dimensions, required rating and verifiable product documentation.
Engineered for extreme thermal resistance and maximum structural endurance in commercial, industrial, and high-occupancy stairwell emergency exits.
Galvannealed Steel Core with Honeycomb / Mineral Rockwool Core
| Fire Rating | 180 Minutes (3.0 Hours) Positive Pressure |
|---|---|
| Door Leaf Material | 18 Ga. (1.2mm) or 16 Ga. (1.5mm) Galvannealed / GI Steel |
| Door Frame | 16 Ga. (1.5mm) or 14 Ga. (2.0mm) Welded / Knock-down Frame |
| Core Insulation | Combustible-Free Mineral Rockwool or High-Density Honeycomb |
| Door Thickness | 1-3/4 Inch (44.5 mm) Standard Commercial Profile |
| Standard Sizes | Single: 3'0" x 7'0" / 4'0" x 8'0" | Double: Up to 8'0" x 8'0" |
| Finish / Coating | Rust-Inhibitive Epoxy Primer or Electrostatic Powder Coating |
| Acoustic & Smoke | UL Listed Intumescent Perimeter Smoke & Draft Gasket Included |
Reinforced with internal vertical steel stiffeners welded along the entire door height for impact endurance.
Mineral rockwool insulation slows radiant thermal transmission, protecting emergency egress corridors.
Factory-prepped reinforced cutouts for heavy-duty panic bars and mortise locksets ensuring zero failure under pressure.
Equipped with intumescent perimeter seals that expand automatically under high temperatures to seal off toxic gases.
Heavy-duty rim and vertical rod fire exit panic bars with exterior trim levers.
Grade 1 adjustable auto-closers tested to over 1,500,000 continuous operation cycles.
4.5" x 4.5" heavy-duty fire-rated stainless steel butt hinges (Grade 304 / 316).
Get custom door scheduling, architectural CAD drawings, test certificates, and competitive project quotations from our team.
From product selection to installation coordination, each scope is planned according to the building requirements and approved specifications.
Product sourcing and specification coordination for fire door requirements in commercial and industrial projects.
Installation coordination for the door leaf, frame, clearances, hardware and interface with the wall opening.
Review of available product test reports, listing details and installation requirements for the specified assembly.
Condition checks to identify visible damage, hardware problems and defects requiring corrective action.
Coordination of compatible hardware selected for the tested door assembly and intended application.
Maintenance enquiries for damaged doors, loose hardware, closing issues and other observable deficiencies.
Fire door ratings must be supported by the applicable test or listing documentation for the complete assembly. Availability varies by product and configuration.
The ratings above are examples of common project specifications, not a guarantee that every rating or size is available. The required rating must be determined from the approved design and applicable building or fire code. Never infer a fire rating from a door's appearance alone.
Fire resistance performance applies to a tested or listed assembly, not simply to the door leaf. The door, frame, hardware, seals, wall construction and installation details must be appropriate for the approved configuration.
Certification marks, standards and ratings are product-specific. Do not advertise a door as UL Listed, BS certified or compliant with a particular standard unless valid supporting documentation is available for that exact assembly.
A structured process helps coordinate the specified door assembly with the actual building opening.
Review opening dimensions, wall construction, door quantity, location and required fire resistance rating.
Confirm the requested door configuration, hardware, finish, certification documents and commercial scope.
Coordinate the approved door assembly and installation according to the product documentation and project scope.
Review door operation, closing and latching functions, visible installation defects and required documentation.
Hardware must be suitable for the particular tested or listed assembly and the intended door application.
Door leaf and frame selected to match the required rating, opening dimensions, wall type and approved product configuration.
Compatible components that support proper movement and reliable self-closing operation where required.
Suitable latching hardware, intumescent seals and smoke seals where specified by the approved design and product documentation.
Product selection depends on the building use, fire compartmentation strategy, approved drawings and applicable regulatory requirements.
Essential information to help you specify and procure fire rated doors for your project.
A fire rated door is part of a tested door assembly designed to provide a specified level of fire resistance for a defined period. Performance depends on the door leaf, frame, hardware, seals, installation and approved configuration.
Contact AJ Fire Safety & Engineering Solutions for fire rated door supply and installation enquiries. Product availability, location, quantity, installation requirements and documentation should be confirmed for each project.
Common specifications may include 60, 90, 120 or 180 minutes. The required rating and available configuration must be verified against the approved building design and the product's valid test or listing documentation.
No. A metal door is not automatically fire rated. The complete door assembly must have appropriate supporting test or listing evidence for the intended rating and installation configuration.
Please provide the door opening width and height, required fire rating, quantity, single or double-leaf configuration, finish, frame details, hardware requirements, site location and required certification.
Some defects may be repairable, but modifications must not compromise the tested or listed assembly. The appropriate repair method and replacement components should be confirmed against the manufacturer's instructions and applicable requirements.
Share your door dimensions, required fire rating, quantity and project location. Our team can discuss product options, installation scope and quotation requirements with you.
AJ FIRE SAFETY & ENGINEERING SOLUTIONS — Your Trusted Fire Safety & Engineering Solution Partner. Product specifications, certification, availability, installation scope and quotations are subject to verification and written agreement.