Loading...
Fire Sprinkler System Company in Bangladesh | Design & Installation | AJ FSES
Automatic Fire Protection

Fire Sprinkler System

Professional automatic fire sprinkler system design, hydraulic calculation, supply, installation, testing, commissioning and maintenance solutions for factories, warehouses, commercial buildings and industrial facilities across Bangladesh.

7+ Years Experience
NFPA Engineering Based
360° Fire Safety Solutions
24/7 Safety Mindset
Automatic Fire Protection Design • Calculation • Installation • Testing
Complete Sprinkler Engineering

Engineered Fire Sprinkler Protection

An automatic fire sprinkler system is an important component of active fire protection. Proper engineering is essential to ensure that the sprinkler network can provide the required water flow and pressure for the designed hazard and occupancy.

AJ FIRE SAFETY & ENGINEERING SOLUTIONS provides complete sprinkler solutions, including site survey, hazard assessment, system design, hydraulic calculation, equipment supply, installation, testing, commissioning and maintenance.

  • Automatic fire sprinkler system design
  • Hydraulic calculation and pipe sizing
  • Sprinkler head layout and spacing
  • Fire pump and water supply coordination
  • Installation, testing and commissioning
Sprinkler Solutions

Sprinkler Systems for Different Applications

Sprinkler configuration and system design are selected according to occupancy, hazard, ceiling arrangement, storage conditions, temperature and applicable engineering requirements.

UP

Upright Sprinkler

Upright sprinkler arrangements for applicable exposed pipe and ceiling configurations.

PN

Pendent Sprinkler

Pendent sprinkler solutions for suitable ceiling and concealed piping applications.

SW

Sidewall Sprinkler

Sidewall sprinkler arrangements for appropriate wall-mounted applications.

CP

Concealed Sprinkler

Concealed sprinkler solutions for projects requiring a cleaner architectural appearance.

ES

Extended Coverage

Applicable extended coverage sprinkler arrangements selected based on listing and design requirements.

SP

Special Application

Project-specific sprinkler solutions for specialized hazards and applications where appropriate.

System Components

Complete Sprinkler System Components

A properly coordinated sprinkler system includes sprinkler heads, piping, valves, water supply, monitoring and associated accessories.

SH

Sprinkler Heads

Appropriate listed sprinkler heads selected according to application and design requirements.

FP

Fire Pump System

Fire pump and water supply coordination to support the sprinkler system hydraulic demand.

VP

Control Valves

Control, isolation and check valve arrangements coordinated with the system.

FM

Flow Monitoring

Water flow and supervisory monitoring components according to system design.

PT

Pressure Monitoring

Pressure gauges and sensing components for system monitoring and verification.

PP

Sprinkler Piping

Main, branch and distribution piping arranged according to hydraulic design.

DT

Drain & Test

Test and drain arrangements for system testing and maintenance.

AC

Accessories

Hangers, supports, fittings, flexible connections and associated accessories.

Sprinkler Hydraulic Engineering Flow • Pressure • Pipe Sizing • Water Demand
Hydraulic Calculation

Designed Around Hydraulic Performance

Sprinkler systems require proper hydraulic analysis to determine the relationship between sprinkler discharge, pipe network, water demand and available pressure.

01
Hazard Classification Project occupancy and applicable hazard criteria.
02
Design Area Determination of applicable hydraulically demanding area.
03
Sprinkler Discharge Flow and pressure relationship for selected sprinklers.
04
Pipe Friction Loss Evaluation of hydraulic losses through the piping network.
05
Elevation Loss Elevation effects considered in system pressure calculations.
06
Water Supply & Pump Duty Final water supply and pump requirements coordinated with the system.
Our Services

Complete Fire Sprinkler Engineering Services

From concept and design through installation, testing and maintenance, AJ FSES provides a complete project lifecycle solution.

01

Site Survey

Review of existing building conditions, occupancy, ceiling configuration and available water supply.

02

Sprinkler Design

Professional sprinkler layout and distribution network design.

03

Hydraulic Calculation

Hydraulic analysis of critical areas, pipe network and water demand.

04

Shop Drawing

Detailed installation drawings and coordinated sprinkler layouts.

05

Material Supply

Supply of sprinkler heads, piping, valves, fittings and associated equipment.

06

Installation

Professional installation and coordination with other building services.

07

Testing & Commissioning

Functional testing, flushing, pressure verification and commissioning support.

08

Maintenance

Inspection, troubleshooting, preventive maintenance and system servicing.

Project Workflow

From Site Survey to System Handover

01

Survey

Site and building assessment.

02

Design

Sprinkler layout engineering.

03

Calculation

Hydraulic system analysis.

04

Installation

Piping and equipment installation.

05

Testing

System performance verification.

06

Handover

Documentation and support.

Codes & Standards

NFPA-Based Fire Sprinkler Engineering

Fire sprinkler system engineering is developed with consideration of applicable codes, standards, authority requirements and project-specific conditions.

NFPA 13 NFPA 20 NFPA 22 NFPA 14 BNBC RSC FSCD Applicable AHJ
Industries We Serve

Sprinkler Protection for Multiple Industries

Garments & Textile Factory
Warehouse & Logistics
Manufacturing Industry
Commercial Buildings
Shopping Malls
High-Rise Buildings
Hospital & Healthcare
Hotel & Hospitality
School & University
Industrial Plant
Power & Utility
Residential & Mixed Use
Why Choose AJ FSES

Professional Fire Sprinkler Engineering Partner

01

Engineering-Based Design

Sprinkler systems are developed around project conditions, occupancy and hydraulic requirements.

02

Hydraulic Calculation

Hydraulic performance is considered during system design and equipment selection.

03

Complete Installation

From sprinkler heads and piping to valves and accessories, the complete system can be coordinated.

04

Testing & Commissioning

System testing and commissioning are included as part of the project workflow.

05

Maintenance Support

Existing sprinkler systems can be inspected, serviced and maintained according to project requirements.

06

Bangladesh Project Experience

Solutions are prepared with practical consideration of local construction and applicable fire safety requirements.

Frequently Asked Questions

Fire Sprinkler System FAQ

An automatic fire sprinkler system is a fixed fire protection system designed to automatically discharge water through individual sprinkler heads when the applicable operating condition is reached.
NFPA 13 is the Standard for the Installation of Sprinkler Systems and is widely used as a technical reference for sprinkler system design and installation.
Yes. AJ FSES provides fire sprinkler hydraulic calculation, pipe sizing, water demand assessment, sprinkler layout and related technical documentation.
Depending on the application and listing requirements, sprinkler systems may use upright, pendent, sidewall, concealed and other appropriate sprinkler configurations.
Yes. We provide fire sprinkler system design and installation solutions for factories, garments and textile facilities, warehouses, industrial plants, commercial buildings and other applicable occupancies.
Yes. Inspection, testing, troubleshooting, preventive maintenance and system performance verification can be provided according to the installed system and project requirements.

Need a Fire Sprinkler System for Your Project?

Contact AJ FIRE SAFETY & ENGINEERING SOLUTIONS for professional fire sprinkler design, hydraulic calculation, supply, installation, testing, commissioning and maintenance.

Get a Project Consultation →